What is a locational net benefit analysis in distribution planning?

A locational net benefit analysis (LNBA) is the exercise that takes "distributed energy resources are valuable" and turns it into a number tied to a specific circuit. Instead of calculating one system-wide avoided cost of DER and applying it everywhere, an LNBA breaks that value down by location, usually by feeder or substation, so planners can see where a new rooftop PV installation, a battery, or a demand response program defers a capital project and where it changes almost nothing on the loading forecast.
The term started showing up in integrated distribution planning filings in states that require utilities to screen non-wires alternatives before approving a traditional upgrade. California's distribution resources plan proceedings are probably where most planners first ran into the acronym, but the underlying logic now shows up in IRP filings, DER interconnection studies, and grid modernization dockets well outside any one state.
What goes into the calculation
An LNBA typically weighs a handful of value streams against each other for a given location:
- Avoided or deferred capacity upgrades, the transformer or conductor replacement that gets pushed out a few years
- Avoided losses on the feeder
- Reduced O&M on equipment that doesn't see the same loading
- Avoided generation and transmission capacity costs, allocated down to the distribution level
- Reliability value, when a DER can act as backup during an outage
The avoided cost of DER is the number you care about from a budgeting standpoint. It's the dollar figure that tells a planning team whether procuring DER at a given location costs less than building the wires-and-transformer solution. An LNBA is the methodology that produces that figure on a location-by-location basis instead of a flat system average.
Where hosting capacity analysis fits in
Hosting capacity analysis and LNBA answer two different questions that get asked back to back. Hosting capacity analysis tells you how much more DER a feeder segment can take before voltage, thermal, or protection limits get tripped. LNBA tells you what that additional DER is worth if it shows up. One sets the ceiling. The other prices what's happening underneath it.
Both calculations lean on the same weak point: knowing current DER penetration on the feeder with any precision. Hosting capacity models need an accurate starting point for existing generation. Avoided cost of DER projections need a credible adoption curve, not a flat percentage copied across every circuit in the territory. Interconnection queue data gets you partway there. It captures what's been formally applied for, but it misses systems installed without a complete application on file, and it tells you nothing about which roofs in a feeder area are even physically capable of hosting a panel array to begin with.
This is the gap that rooftop-level imagery analysis closes. Roof plane geometry, usable area by orientation, and installed-panel detection by feeder give a planning team a real adoption count to anchor the DER forecast an LNBA depends on, rather than extrapolating from queue data and a regional saturation guess. Rooftop Solar Potential builds that layer from annual aerial imagery passes, scoring individual roof planes for solar viability and flagging which ones went from bare to panelled year over year, organized by feeder.
A quick glossary note
If you're putting together a distribution planning glossary for new hires, it's worth drawing a clean line between these three terms, because they get used almost interchangeably in some filings even though they answer different questions:
- Hosting capacity analysis: how much more DER this feeder segment can absorb
- Locational net benefit analysis: what DER at this location is worth, in avoided cost terms
- Avoided cost of DER: the dollar output of an LNBA, the figure compared against the cost of a traditional capital upgrade
None of the three tells you how much rooftop PV is actually out there right now. That's a separate data problem, and it's the one that determines whether the first two numbers are grounded in reality or in a planning assumption nobody has checked against the roofs themselves.
Want a feeder-level count of usable roof area and year-over-year panel adoption to plug into your own LNBA inputs? Rooftop Solar Potential runs that pass annually from satellite and aerial imagery.